A. NFPA recommends one 2-A fire extinguisher for square feet. OSHA requires employees to have access to an extinguisher within 75 feet. B. Employees should have access to a fire extinguisher within either 30 or 50 feet, depending on the hazard in question and the rating of …
In the hands of trained personnel, portable fire extinguishers are the first line of defense against incipient fires, but in order to be useful they need to be accessible. … maximum travel distance then people might have to travel the entire 75 ft to get the extinguisher and then back another 75 ft to return to the fire in order to extinguish …
NFPA Requirements For Mounting a Fire Extinguisher
The maximum floor area for this type is set ft 2. For more information, see tables 6.2.1.1 and 6.3.1.1 in NFPA 10. The smaller of the required distances between fire extinguishers should be chosen. This is because if each fire extinguisher requires 75 ft. of walking, then the average person may take up to 30 seconds to grab a fire …
It states that in all cases you must be within 75 feet of an extinguisher (keep 75′ feet in mind, it can never be further). Then they talk about the type of hazard. In a light hazard occupancy you must have a minimum 2-A extinguisher, it can sf per A. …
People Also Ask when was the fire extinguisher 75 feet rule made
How far can a fire extinguisher protrude from the floor?
As long as the bottom of the extinguisher is no higher than 27 inches from the floor, it can protrude as far as you like into the walkway because it is within reach of the cane. Any higher than 27 inches, and it can only protrude four inches from the wall.
What does NFPA 10 say about fire extinguishers?
When NFPA 10 addresses extinguisher placement it uses the term “maximum travel distance to extinguisher”. This means that at any point inside the building you should never have to travel more than the maximum distance to reach an extinguisher.
What are the OSHA fire extinguisher placement rules?
The OSHA fire extinguisher placement rules depend on the class of fire you expect to encounter. There are five classes of fire and this table shows the characteristics of the fire and the type of extinguisher needed to combat it. Carbon dioxide, dry chemical, clean agent. Not water under any circumstances.
How do I choose the right fire extinguisher?
The first step is to choose the correct extinguisher based on the fire risk. Extinguishers are broken down into the following ratings: The distribution of portable fire extinguishers is a balance between having an extinguisher nearby when you need it but not being overly burdened by the cost and maintenance of having excessive extinguishers.