Do fire extinguishers need to be commissioned

If the extinguisher is to be used in a commercial or public building – it will need to be commissioned on site after delivery. You will need a BAFE approved fire extinguisher engineer (a person with the knowledge and training that allows them to competently service portable fire extinguishers in accordance with the requirements of BS 5306 Part 3).

Non-rechargeable fire extinguishers: If your fire extinguishers are non-rechargeable (for one-time use only), then they require neither the 6-year or 12-year maintenance procedures. Rather, they must be removed from service by no later than 12 years after their manufacture date. Trust Koorsen With Your Fire Extinguisher Maintenance

OSHA Fire Extinguisher Height, Placement, and …

How far apart do fire extinguishers need to be? The distance between fire extinguishers depends on the type of fire that is likely to occur and the class of extinguishers you have. It ranges from 30 feet for some types of Class B extinguisher to within 75 feet for Class A and a maximum of 75 feet from a Class D hazard.

Also Check:  Are landlords required to provide fire extinguishers

Under British Standard BS 5306-3:2009, “The commissioning of an extinguisher should be carried out by a competent person.”. So, when you need to commission fire extinguishers that have been delivered and unpacked, you must appoint a competent person to undertake a series of checks.

People Also Ask do fire extinguishers need to be commissioned

Can I hire a professional to commission a fire extinguisher?

If you do not have a trained, competent person available, or your company is not large enough to warrant training one, you can hire a fire safety professional to do this for you on an ‘as required’ basis. You do not need to enter into a hire contract for fire extinguisher maintenance just to get help with commissioning new fire extinguishers.

Also Check:  Why two fire extinguisher war thunder

What are the most frequently asked questions about fire extinguishers?

As a sales administrator for the Fire Protection Shop, the most frequently asked question I get, usually on a daily basis is: “Why do fire extinguishers need commissioning if they are new?” OR “Why does this have to be done on site?”

What qualifications do I need to service a portable fire extinguisher?

You will need a BAFE approved fire extinguisher engineer (a person with the knowledge and training that allows them to competently service portable fire extinguishers in accordance with the requirements of BS 5306 Part 3).

Can a brand new fire extinguisher be taken out of the box?

It is tempting to assume that if you buy a brand new fire extinguisher from a dealer or online, that they have been set up in the factory, and can simply be taken out of the box, ready for use. This is not correct. Under British Standard BS 5306-3:2009, “The commissioning of an extinguisher should be carried out by a competent person.”

Also Check:  How to get rid of out of date fire extinguishers

People Also Searches do fire extinguishers need to be commissioned

Fire Extinguisher Installation and Commissioning Explained Video Answer


Reference:
https://www.usfa.fema.gov/