Any higher than 27 inches, and it can only protrude four inches from the wall. Under the ADA accessibility guidelines, if you use a fire extinguisher cabinet, the cabinet handle must be at a height that is accessible to a person in a wheelchair. This is to allow them the same access as an able-bodied person.
Nearby (with Arrows) – Putting up signs down the hall, or around the corner, from the actual fire extinguisher can be a good idea, but only if the sign has arrows pointing people where to go. OSHA and other safety organizations don’t have strict rules on exactly where these signs need to be placed. Instead, they simply say that a facility …
NFPA Requirements For Mounting a Fire Extinguisher
How High To Mount a Fire Extinguisher? Fire extinguishers can only be mounted between 4 inches and 5 ft. from the ground to the top of the canister. However, fire extinguishers that weigh more than 40 lbs. can only sit a maximum of 3ft. 6 in. off the ground to the top of the canister. If the fire extinguisher is wheeled, it does not require mounting.
According to the ADA, if an object is mounted to the wall (like fire extinguishers often are), and their leading edges are located between 27 inches and 80 inches above the finished floor, the mounted object can protrude no more than four inches into walkways, corridors, passageways, or aisles.
People Also Ask how high can a fire extinguisher be mounted
How high should a fire extinguisher be mounted?
Larger fire extinguishers need to be mounted at lower heights with the carrying handle about 3 feet from the floor. And finally, let’s turn our attention to OSHA’s fire extinguisher signage requirements.
How many 2 a fire extinguishers are required in a building?
NFPA recommends one 2-A fire extinguisher for every 3,000 square feet. OSHA requires employees to have access to an extinguisher within 75 feet. Employees should have access to a fire extinguisher within either 30 or 50 feet, depending on the hazard in question and the rating of the extinguisher (see below).
How much clearance do you need for a portable fire extinguisher?
According to the Extinguisher Placement and Safety page of OSHA’s Evacuation Plans and Procedures eTool, there must be at least four inches clearance between the floor and the bottom of a portable extinguisher.
How do you display a fire extinguisher in your home?
Place a sign or something similar that makes it easy for people to know where an extinguisher is/extinguishes are. Consider placing it so it can be seen well from up close, at a distance, and from different angles.
People Also Searches how high can a fire extinguisher be mounted
fire extinguisher hanging height |
osha fire extinguisher monthly checklist |
fire extinguisher height from floor |
osha fire extinguisher placement rules |
nfpa fire extinguisher clearance requirements |
building codes for fire extinguishers |
table 6.2.1.1 of nfpa 10 |
nfpa 10 fire extinguisher requirements |
Fire Extinguisher FAQs – How High Do Fire Extinguishers Need to be Mounted? Video Answer
Reference:
https://www.usfa.fema.gov/
https://en.wikipedia.org/wiki/Fire_extinguisher