If you have a dry chemical extinguisher, you should have it hydrotested every 12 years. This should give you a good sense of the kind of maintenance you need to perform on your fire extinguishers and the intervals at which that maintenance must occur.
If you have a water, foam, powder or chemical extinguisher, after that every 5 years the fire extinguisher will require an extended servicing which includes: Discharging the extinguisher. Checking of the fire extinguisher for rust and damages. Check removable parts for rust or damages and change as necessary.
How often do my fire extinguishers need to be serviced?
In addition, most fire extinguishers are required to have maintenance performed on them every 6 years from the manufacture date of the extinguisher. Please see list below for exact frequency of service and type of service required for the different types of extinguishers. ABCrequire an internal maintenance every 6 years and a hydrostatic test every 12 years from the date that the …
Even in pristine condition, a fire extinguisher should be replaced every 12 years and may need to be recharged after 6. Anyone who lights candles, cooks often or just has matches in the house can …
People Also Ask how often to service a fire extinguisher
How often should a fire extinguisher be serviced?
Discharging the extinguisherChecking of the fire extinguisher for rust and damagesCheck removable parts for rust or damages and change as necessaryRinse water-based fire extinguishers out with waterRefill & re-pressurise the extinguisher
How long does it take to service a fire extinguisher?
Usually, these should be carried out every 5 years however CO2 extinguishers only need an extended service every 10 years. An extended service includes a discharge test to check the internal systems for signs of corrosion, a valve service, refilling and repressuring.
How often should I Have my Fire extinguisher inspected?
Visual Fire Extinguisher Inspections – Once per MonthLook for obvious signs of physical damage, such as corrosion, leakage, or dents.Check the pressure gauge to make sure the indicator is in the operating range.Make sure the pull-pin is not missing and the pull pin seal is intact.Verify the date of the last professional inspection.
More items…
How often must fire extinguishers be recharged?
When and why do fire extinguishers need to be recharged?Fire extinguishers need to be recharged immediately after each use. …Fire extinguishers need to be recharged periodically throughout their life, even if they haven’t been used. …Extinguishers can also need to be internally examined or recharged due to damage or other environmental factors that may result in them becoming depressurized.
People Also Searches how often to service a fire extinguisher
fire extinguisher hydro test frequency |
fire extinguisher inspection frequency |
fire extinguisher service intervals |
how to service fire extinguishers |
fire extinguisher service requirements |
fire extinguisher testing frequency |
how long are fire extinguishers good |
how to recharge a fire extinguisher |
How often do Fire Extinguisher's need to be Serviced? Video Answer
Reference:
https://www.usfa.fema.gov/
https://en.wikipedia.org/wiki/Fire_extinguisher